COMMENT This file, slow.mod, implements the Slow [Ca2+] sensor (S) from Liu et al. 1998 (Activity dependent conductances) Tom M Morse 20070807 Note that the transition rates depend on the Ca current, ica, rather than on the membrane voltage. ENDCOMMENT NEURON { SUFFIX S USEION ca READ ica RANGE S } UNITS { (mA) = (milliamp) } PARAMETER { G = 3 : p2312 after eqn. 4 tau_M = 50 (ms) : p. 2313, table 2 tau_H = 60 (ms) : table 2 also Z_M = 7.2 : table 2 also Z_H = 2.8 : table 2 also } ASSIGNED { Mbar (1) : Mbar and Hbar play the roles of m_inf, h_inf in Hbar (1) : standard HH models ica (mA/cm2) S (1) } STATE { M H } BREAKPOINT { SOLVE states METHOD cnexp S = G * M * M * H : note there is no driving force } INITIAL { : assume that ica has been constant for a long time at startup rates(ica) M = Mbar H = Hbar } DERIVATIVE states { rates(ica) M' = (Mbar - M)/tau_M H' = (Hbar - H)/tau_H } PROCEDURE rates(ica (mA/cm2)) { UNITSOFF Mbar = 1/(1+exp( Z_M + 1e3*ica )) : mA/cm2 is 1e-3*nA/nF when Hbar = 1/(1+exp( -Z_H - 1e3*ica )) : specific capacitance= 1 uF/cm2 UNITSON }