SenseLab
Computational model
  Data
Reliability of Morris-Lecar neurons with added T, h, and AHP currents (Zeldenrust et al. 2013)
We investigated the reliability of the timing of spikes in a spike train in a Morris-Lecar model with several extensions. A frozen Gaussian noise current, superimposed on a DC current, was injected. The neuron responded with spike trains that showed trial-to-trial variability. The reliability depends on the shape (steepness) of the current input versus spike frequency output curve. The model also allowed to study the contribution of three relevant ionic membrane currents to reliability: a T-type calcium current, a cation selective h-current and a calcium dependent potassium current in order to allow bursting, investigate the consequences of a more complex current-frequency relation and produce realistic firing rates.
  • Neuron or other electrically excitable cell Show Other
  • Zeldenrust F, Chameau PJ, Wadman WJ (2013) Show Other
  • Zeldenrust, Fleur [fleurzeldenrust at gmail.com] Show Other
fleurzeldenrust@gmail.com
Morris-Lecar neuron
Reliability
Zeldenrust, Fleur <fleurzeldenrust@gmail.com>
PMID: 23708878
False
False
Other categories referring to Reliability of Morris-Lecar neurons with added T, h, and AHP currents (Zeldenrust et al. 2013)
Revisions: 7
Last Time: 6/5/2013 10:58:58 AM
Reviewer: Tom Morse - MoldelDB admin
Owner: Tom Morse - MoldelDB admin