Massobrio G, Martinoia S, Massobrio P (2018) Equivalent Circuit of the Neuro-Electronic Junction for Signal Recordings From Planar and Engulfed Micro-Nano-Electrodes. IEEE Trans Biomed Circuits Syst 12:3-12 [PubMed]

   The neuro-electronic junction (planar and engulfed electrodes) (Massobrio et al 2018)

References and models cited by this paper

References and models that cite this paper

Angle MR, Cui B, Melosh NA (2015) Nanotechnology and neurophysiology. Curr Opin Neurobiol 32:132-40 [Journal] [PubMed]

Chua LO (1980) Device modeling via basic nonlinear circuit elements IEEE Trans. Circuits Syst. 27:1014-44

Cohen A, Shappir J, Yitzchaik S, Spira ME (2008) Reversible transition of extracellular field potential recordings to intracellular recordings of action potentials generated by neurons grown on transistors. Biosens Bioelectron 23:811-9 [Journal] [PubMed]

Fendyur A, Mazurski N, Shappir J, Spira ME (2011) Formation of Essential Ultrastructural Interface between Cultured Hippocampal Cells and Gold Mushroom-Shaped MEA- Toward "IN-CELL" Recordings from Vertebrate Neurons. Front Neuroeng 4:14 [Journal] [PubMed]

Franks W, Schenker I, Schmutz P, Hierlemann A (2005) Impedance characterization and modeling of electrodes for biomedical applications. IEEE Trans Biomed Eng 52:1295-302 [Journal] [PubMed]

Fromherz P (2003) Neuroelectronic interfacing: Semiconductor chips with ion channels, nerve cells, and brain Nanoelectronics and Information Technology :781-810

Ghazavi A, Westwick D, Xu F, Wijdenes P, Syed N, Dalton C (2015) Effect of planar microelectrode geometry on neuron stimulation: finite element modeling and experimental validation of the efficient electrode shape. J Neurosci Methods 248:51-8 [Journal] [PubMed]

Gross GW,Rhoades BK,Jordan RJ (1992) Neuronal networks for biochemical sensing Sens Actuators B-Chem 6:1-8

Hai A, Dormann A, Shappir J, Yitzchaik S, Bartic C, Borghs G, Langedijk JP, Spira ME (2009) Spine-shaped gold protrusions improve the adherence and electrical coupling of neurons with the surface of micro-electronic devices. J R Soc Interface 6:1153-65 [Journal] [PubMed]

Hai A, Shappir J, Spira ME (2010) In-cell recordings by extracellular microelectrodes. Nat Methods 7:200-2 [Journal] [PubMed]

HODGKIN AL, HUXLEY AF (1952) A quantitative description of membrane current and its application to conduction and excitation in nerve. J Physiol 117:500-44 [Journal] [PubMed]

   Squid axon (Hodgkin, Huxley 1952) (LabAXON) [Model]
   Squid axon (Hodgkin, Huxley 1952) (NEURON) [Model]
   Squid axon (Hodgkin, Huxley 1952) (SNNAP) [Model]
   Squid axon (Hodgkin, Huxley 1952) used in (Chen et al 2010) (R language) [Model]
   Squid axon (Hodgkin, Huxley 1952) (SBML, XPP, other) [Model]

Keefer EW, Botterman BR, Romero MI, Rossi AF, Gross GW (2008) Carbon nanotube coating improves neuronal recordings. Nat Nanotechnol 3:434-9 [Journal] [PubMed]

Kovacs GT (1994) Microelectrode models for neural interfaces Enabling Technologies For Cultured Neural Networks :121-165

Lee KY, Shim S, Kim IS, Oh H, Kim S, Ahn JP, Park SH, Rhim H, Choi HJ (2009) Coupling of semiconductor nanowires with neurons and their interfacial structure. Nanoscale Res Lett 5:410-5 [Journal] [PubMed]

Liu R, Chen R, Elthakeb AT, Lee SH, Hinckley S, Khraiche ML, Scott J, Pre D, Hwang Y, Tanaka A, Ro YG, Matsushita AK, Dai X, Soci C, Biesmans S, James A, Nogan J, Jungjohann KL, Pete DV, Webb DB, Zou Y, Bang AG, Dayeh SA (2017) High Density Individually Addressable Nanowire Arrays Record Intracellular Activity from Primary Rodent and Human Stem Cell Derived Neurons. Nano Lett 17:2757-2764 [Journal] [PubMed]

Marom S, Shahaf G (2002) Development, learning and memory in large random networks of cortical neurons: lessons beyond anatomy. Q Rev Biophys 35:63-87 [PubMed]

Martinoia S, Massobrio P, Bove M, Massobrio G (2004) Cultured neurons coupled to microelectrode arrays: circuit models, simulations and experimental data. IEEE Trans Biomed Eng 51:859-64 [Journal] [PubMed]

Massobrio P, Martinoia S (2008) Modelling small-patterned neuronal networks coupled to microelectrode arrays. J Neural Eng 5:350-9 [Journal] [PubMed]

Massobrio P, Massobrio G, Martinoia S (2007) Multi-program approach for simulating recorded extracellular signals generated by neurons coupled to microelectrode arrays Neurocomputing 70:2467-2476 [Journal]

Massobrio P, Massobrio G, Martinoia S (2016) Interfacing Cultured Neurons to Microtransducers Arrays: A Review of the Neuro-Electronic Junction Models. Front Neurosci 10:282 [Journal] [PubMed]

MAURO A (1961) Anomalous impedance, a phenomenological property of time-variant resistance. An analytic review. Biophys J 1:353-72 [PubMed]

McIntyre CC, Grill WM (2001) Finite element analysis of the current-density and electric field generated by metal microelectrodes. Ann Biomed Eng 29:227-35 [PubMed]

McIntyre CC, Grill WM (2002) Extracellular stimulation of central neurons: influence of stimulus waveform and frequency on neuronal output. J Neurophysiol 88:1592-604 [Journal] [PubMed]

Nicolelis MA (2003) Brain-machine interfaces to restore motor function and probe neural circuits. Nat Rev Neurosci 4:417-22 [Journal] [PubMed]

Nunez PL, Srinivasan R (2006) Electric fields of the brain: the neurophysics of EEG 2nd ed.

Ojovan SM, Rabieh N, Shmoel N, Erez H, Maydan E, Cohen A, Spira ME (2015) A feasibility study of multi-site,intracellular recordings from mammalian neurons by extracellular gold mushroom-shaped microelectrodes. Sci Rep 5:14100 [Journal] [PubMed]

Pinto TM, Wedemann RS, Cortez CM (2014) Modeling the electric potential across neuronal membranes: the effect of fixed charges on spinal ganglion neurons and neuroblastoma cells. PLoS One 9:e96194 [Journal] [PubMed]

Quian Quiroga R, Panzeri S (2009) Extracting information from neuronal populations: information theory and decoding approaches. Nat Rev Neurosci 10:173-85 [Journal] [PubMed]

Ramo S,Whinnery JR,Van Duzer T (1994) Fields and Waves in Communication Electronics

Robinson DA (1968) The electrical properties of metal microelectrodes Proc IEEE 56:1065

Samhaber R, Schottdorf M, El Hady A, Bröking K, Daus A, Thielemann C, Stühmer W, Wolf F (2016) Growing neuronal islands on multi-electrode arrays using an accurate positioning-µCP device. J Neurosci Methods 257:194-203 [Journal] [PubMed]

Santoro F, Dasgupta S, Schnitker J, Auth T, Neumann E, Panaitov G, Gompper G, Offenhäusser A (2014) Interfacing electrogenic cells with 3D nanoelectrodes: position, shape, and size matter. ACS Nano 8:6713-23 [Journal] [PubMed]

Santoro F, Panaitov G, Offenhäusser A (2014) Defined patterns of neuronal networks on 3D thiol-functionalized microstructures. Nano Lett 14:6906-9 [Journal] [PubMed]

Santoro F, Schnitker J, Panaitov G, Offenhäusser A (2013) On chip guidance and recording of cardiomyocytes with 3D mushroom-shaped electrodes. Nano Lett 13:5379-84 [Journal] [PubMed]

Schottdorf M, Hofmann B, Kätelhön E, Offenhäusser A, Wolfrum B (2012) Frequency-dependent signal transfer at the interface between electrogenic cells and nanocavity electrodes. Phys Rev E Stat Nonlin Soft Matter Phys 85:031917 [Journal] [PubMed]

Segev I, Fleshman JW, Burke RE (1989) Compartmental models of complex neurons Methods In Neuronal Modelling: From Synapses To Networks, Koch C:Segev I, ed. pp.63

Siu WM,Cobbold RSC (1979) Basic properties of the electrolyteSiO2 -Si system: Physical and theoretical aspects IEEE Trans Electron Devices 26(11):1805-1815

Spanu A, Lai S, Cosseddu P, Tedesco M, Martinoia S, Bonfiglio A (2015) An organic transistor-based system for reference-less electrophysiological monitoring of excitable cells. Sci Rep 5:8807 [Journal] [PubMed]

Storace M, Bove M, Grattarola M, Parodi M (1997) Simulations of the behavior of synaptically driven neurons via time-invariant circuit models. IEEE Trans Biomed Eng 44:1282-7 [Journal] [PubMed]

Tang M, Song Q, Li N, Jiang Z, Huang R, Cheng G (2013) Enhancement of electrical signaling in neural networks on graphene films. Biomaterials 34:6402-11 [Journal] [PubMed]

Thakore V, Molnar P, Hickman JJ (2012) An optimization-based study of equivalent circuit models for representing recordings at the neuron-electrode interface. IEEE Trans Biomed Eng 59:2338-47 [Journal] [PubMed]

Yates DE,Levine S,Healy TW (1974) Site-binding model of the electrical double layer at the oxide/water interface J Chem Soc Farady Trans 70:1807-1818

Zhang A, Lieber CM (2016) Nano-Bioelectronics. Chem Rev 116:215-57 [Journal] [PubMed]

(43 refs)